ventilation

The main purpose of the ventilation system is to create a microclimate in industrial premises that provides favorable conditions for the performance of work. No less important is the second task of the ventilation system — purification from harmful substances of the air released into the atmosphere by ventilation systems of enterprises. Protecting the air environment from industrial pollution is an important social and national task in our country, which is part of the complex of tasks of the global problem of nature protection.

Purpose of the ventilation system
The surrounding air is a mixture of gases, consisting mainly of nitrogen, oxygen and water vapor (moisture). Air that does not contain water vapor is called dry, and air that contains it is called wet. The composition of dry air includes (% by volume): nitrogen — 78.13; oxygen — 20.9; inert gases — 0.94; carbon dioxide — 0.03. In practice, ventilation has to deal only with moist air. Depending on meteorological conditions, the water vapor content ranges from 0.5 to 25 g per 1 kg of air.

entilation The air condition is characterized by its main parameters: temperature, relative humidity, mobility (speed) and barometric pressure. Relative humidity is the ratio of the mass of water vapor contained in moist air to the mass of water vapor saturating (as much as possible) the same volume of air at the same temperature. The relative humidity of the air is expressed as a percentage.

A person feels good only in a fairly narrow range of combinations of various air parameters. In accordance with GOST 12.1.005—76 "Working area air" in the working area of premises (a space 2 m high from the floor or 1.5 m if people are in a sitting position), it is necessary to maintain certain air parameters, taking into account the category of severity of work (light, moderate or severe), the time of year and the amount of excess heat, standing out in the rooms.

In industrial premises, there is no need to maintain the required air parameters throughout the entire volume. It is important that only in the area where people are located or in places near technological equipment, the air parameters do not deviate from the normalized limits. The air parameters of the ventilation system can be optimal, in which a person feels neither heat nor cold, feels comfortable, and acceptable, in which a person's well-being and productivity slightly differ from optimal. Thus, for industrial premises in the cold season, the following optimal air parameters are set for moderate work: temperature 18-20 ° C, relative humidity 40-60% and mobility no more than 0.2 m/s. Acceptable air parameters for the same conditions have a wider range: temperature 17-23 ° C, relative humidity no higher than 75% (the lower limit is not limited) and the mobility is not more than 0.3 m/s. Maintenance of certain air parameters is regulated by SNiP 2.04.05—86 "Heating, ventilation and air conditioning. Design standards". In industrial premises, maintenance of acceptable air parameters is most often provided.
Production processes may be accompanied by the release of gases and vapors harmful to humans into the air of the working area of the premises, the amount of which depends on the specifics of the technological process, the degree of sealing of the equipment, etc. The content of harmful gases and vapors in the air of the working area should not exceed the maximum permissible concentration (MPC). The maximum permissible concentration is the maximum possible amount of a harmful substance, mg/m3, per unit volume of air, which during the entire length of service does not cause diseases or abnormalities in the health of people working in these conditions, and does not affect subsequent generations. GOST 12.1.005—76 regulates the maximum permissible concentration for 646 different harmful substances. In addition, a large amount of heat, both convective and radiant, can come from technological equipment, requiring the creation of a certain air mobility in workplaces prone to blistering, as well as moisture and dust. The person involved in the production process is himself a generator of heat, moisture, dust and carbon dioxide. * ventilation in Samara, in most cases, can provide only acceptable sanitary and hygienic conditions in the premises. The air parameters, which are strictly defined by temperature and relative humidity, including optimal ones, are ensured by the use of air conditioning systems. Air and air-heat curtains are designed to protect gates and open openings of industrial buildings from the intake of cold air in winter. There are two types of curtains: sliding, in which a flat stream of air is supplied either from below or from the sides of openings and gates at a certain angle to meet the cold air, and mixing, when air from a building or workshop is supplied to the vestibule between the double entrance doors. Mixing curtains are used in administrative and public buildings, in passageways, etc. Curtains in which the air is preheated in an air heater are called air-thermal, and curtains that supply air without heating are simply air.
Pricing policy for installation, maintenance and repair ventilation systems in Samara is provided
The company's SERVICE MANAGER.
contact phone number in RUSSIA:

В производственных помещениях нет необходимости поддерживать требуемые параметры воздуха по всему объему. Важно, чтобы только в зоне, где находятся люди, или в местах у технологического оборудования параметры воздуха не отклонялись от нормируемых пределов.
Параметры воздуха системы вентиляции могут быть оптимальными, при которых человек не ощущает ни тепла, ни холода, чувствует себя комфортно, и допустимыми, при которых самочувствие человека и производительность его труда незначительно отличаются от оптимальных. Так, для производственных помещений в холодный период года при работе средней тяжести установлены следующие оптимальные параметры воздуха: температура 18—20°С, относительная влажность 40—60 % и подвижность не более 0,2 м/с.
Допустимые параметры воздуха для тех же условий имеют более широкий диапазон: температура 17—23 °С, относительная влажность не выше 75% (нижний предел не лимитируется) и подвижность не более 0,3 м/с. Поддержание тех или иных параметров воздуха регламентируется СНиП 2.04.05—86 «Отопление, вентиляция и кондиционирование воздуха. Нормы проектирования». В производственных помещениях наиболее часто предусматривается поддержание допустимых параметров воздуха.
Производственные процессы могут сопровождаться выделением в воздух рабочей зоны помещений вредных для человека газов и паров, количество которых зависит от особенностей технологического процесса, степени герметизации оборудования и пр. Содержание вредных газов и паров в воздухе рабочей зоны не должно превышать предельно допустимой концентрации (ПДК).
Предельно допустимая концентрация — это максимально возможное количество вредного вещества, мг/м3, в единице объема воздуха, которое в течение всего рабочего стажа не вызывает заболеваний или отклонений в состоянии здоровья людей, работающих в данных условиях, и не сказывается на последующих поколениях. ГОСТ 12.1.005—76 регламентирует ПДК для 646 различных вредных веществ. Кроме того, от технологического оборудования может поступать большое количество тепла как конвективного, так и лучистого, требующего создания определенной подвижности воздуха на рабочих местах, подверженных блучению, а также влага и пыль. Человек, участвующий в производственном процессе, сам является генератором тепла, влаги, пыли и углекислого газа.
вентиляция в Самаре в большинстве случаев может обеспечить в помещениях только допустимые санитарно-гигиенические условия. Параметры воздуха, строго определенные по температуре и относительной влажности, в том числе и оптимальные, обеспечиваются применением систем кондиционирования воздуха.
Воздушные и воздушно-тепловые завесы предназначены для защиты ворот и открытых проемов промышленных зданий от поступления холодного воздуха в зимний период. Различают два типа завес: шибирующие, у которых плоская струя воздуха подается либо снизу, либо с боков проемов и ворот под некоторым углом на встречу холодному воздуху, и смесительные, когда воздух из здания или цеха подается в тамбур между двойными входными дверями. Смесительные завесы применяют в административно-общественных зданиях, в проходных и т. д. Завесы, в которых воздух предварительно нагревается в воздухонагревателе, называются воздушно-тепловыми, а завесы, подающие воздух без нагрева,— просто воздушными.
Ценовая политика по монтажу, сервисному обслуживанию и ремонту системы вентиляции в Самаре предоставляется
МЕНЕДЖЕРОМ ПО СЕРВИСУ компании.
контактный тел в Самаре:

                                                                         

  Вентиляция в Самаре                 т. 8(908)-382-39-20

                                                       т. ​8(927)-760-50-12